1U AC backup power for critical electronics
The Acumentrics ANB1501 is a rugged uninterruptible power supply for defence, aerospace and other applications where rack space is limited and an interruption to AC power can take critical equipment offline. Its 1U chassis makes it suitable for integration into racks housing communications equipment, network hardware and other sensitive AC-powered electronics.
The online double-conversion design supplies a sine-wave AC output and helps protect connected equipment from disturbances such as input voltage sags and surges. If the AC supply fails, the UPS transfers to its internal battery without interrupting the output.
Key features
- 1,500 VA / 1,250 W continuous output. Provides conditioned AC power and battery backup in a 1U chassis.
- Wide AC input range. Accepts 80–265 V AC at 47–440 Hz, making it suitable for projects with varied AC supplies.
- Two AC output configurations. Choose 115 V AC / 60 Hz or specify the optional 230 V AC / 50 Hz configuration to suit the connected equipment.
- Hot-swappable battery packs. Choose lithium iron phosphate (LFP) or valve-regulated lead-acid (VRLA) to suit your runtime and weight requirements.
- Optional paralleling and N+1 redundancy. Configure compatible units to share load or build in redundancy. Metromatics can help confirm a configuration for your critical load.
- UPS communications. SNMP v3 and RS-232 are listed in the manufacturer’s specifications. Confirm the communications options for the part number you order.
Battery runtime
At a 1,000 W load, Acumentrics lists 13 minutes with LFP and 6 minutes with VRLA. At the 1,250 W rated load, published runtime is 10 minutes with LFP and 2 minutes with VRLA. Use the table to compare the battery options at your expected load.
| Connected load | LFP runtime | VRLA runtime |
|---|---|---|
| 250 W | 53 min | 33 min |
| 500 W | 28 min | 14 min |
| 750 W | 18 min | 8 min |
| 1,000 W | 13 min | 6 min |
| 1,250 W | 10 min | 2 min |
Published recharge time is 4 hours for LFP and 5 hours for VRLA.
LFP = lithium iron phosphate. VRLA = valve-regulated lead-acid.
Technical Specifications
| Specification | Acumentrics ANB1501 |
|---|---|
| Form factor | 1U rugged rackmount UPS |
| UPS topology | Online double conversion |
| Continuous output power | 1,500 VA / 1,250 W |
| AC input | 80–265 V AC, 47–440 Hz |
| AC output | 115 V AC / 60 Hz or optional 230 V AC / 50 Hz |
| Output waveform | Sine wave |
| Battery options | Hot-swappable LFP or VRLA |
| Chassis dimensions | 45 × 432 × 554 mm (H × W × D) |
| Overall envelope | 45 × 495 × 629 mm (H × W × D) |
| Weight | 9.1 kg without battery, 12.7 kg with LFP, 15.0 kg with VRLA |
| Operating temperature | −20°C to +55°C. Derating applies at specification extremes. |
| Communications | SNMP v3 and RS-232. Confirm configuration when ordering. |
Environmental and platform requirements
Acumentrics lists specific test methods and requirements under MIL-STD-810G for environmental conditions, shock and vibration, and MIL-STD-461F for electromagnetic compatibility. The datasheet also identifies applicable airborne and shipboard requirements. For a tender or platform specification, send Metromatics the required standard, revision, test method and acceptance criteria so we can confirm the evidence available for your configuration.
Download the Acumentrics ANB1501 datasheet (PDF)
Acumentrics ANB1501 CE Rugged UPS
The Acumentrics ANB1501 CE is a CE-marked version of the 1U Rugged Blade UPS for projects that specify CE compliance. It delivers 1,500 VA / 1,250 W of continuous AC output. Acumentrics lists EN 62040-1, EN 62040-2 and EN 50581 in the CE model’s datasheet.
If your project requires CE marking, specify ANB1501 CE when requesting a quote. Tell us your available AC input supply and required output voltage and frequency so we can confirm the ordering part number and applicable conformity documentation.
Download the Acumentrics ANB1501 CE datasheet (PDF)
Request an ANB1501 quote
Tell us your AC input supply, required output voltage and frequency, connected load, backup runtime and available rack space. If your project also requires redundancy or compliance with specific test methods, include those details so we can help you select the right ANB1501 configuration.
Discuss Your Rugged UPS Requirements