Donut Through-Hole Load Cell LTH300

The Donut Through-Hole Load Cell LTH300 is a compact, high-precision Donut Through-Hole Load Cell designed for inline compression and bolt-force applications. Its smooth thru-hole design allows structural members or bolts to pass through the sensor without interference, making it ideal for clamping, press monitoring, and inline compression measurement in tight assemblies.

Key Features & Benefits of the Donut Through-Hole Load Cell LTH300

  • Clear Through-Hole Design – Enables a sensor ring around a load path, allowing structures, bolts, shafts, or fixtures to pass through unimpeded.

  • Compact & Low Profile – Only ~0.28 in (7.1 mm) height with an outer diameter near 0.98 in (24.9 mm), enabling integration into space-constrained systems.

  • Flexible Inner Diameter Options – Inner diameters (I.D.) from 1/8″ (3.2 mm) to 3/8″ (9.5 mm) available to match your bolt or shaft dimensions.

  • High Accuracy & Responsiveness – Rated output ~2 mV/V, nonlinearity ±0.5 % of RO, nonrepeatability ±0.5 % RO, and minimal deflection (~0.001 in).

  • Robust Mechanical & Electrical Design – 17-4 PH stainless steel construction, 700 Ω bridge, robust strain relief, IP64 rating.

  • Overload Protection & Durability – Safe overload rated at 150 % of RO, protecting against transient loads.

  • Wide Operating Temperature Range – −60 °F to +200 °F (−50 °C to +93 °C); compensated from 60 to 160 °F.

  • Low Power & Low Deflection – Minimal deflection and energy usage make it suitable for dynamic and responsive measurement systems.


Technical Specifications of the Donut Through-Hole Load Cell LTH300

ParameterDetail
Capacities50 lb, 100 lb, 250 lb, 500 lb, 1,000 lb (various options)
Rated Output (RO)2 mV/V nominal
Nonlinearity±0.5 % of RO
Hysteresis±0.5 % of RO (or per specs)
Nonrepeatability±0.5 % of RO
Safe Overload150 % of RO
Bridge Resistance700 ohm nominal
Insulation Resistance≥ 500 MΩ @ 50 VDC
Material17-4 PH stainless steel
Deflection~0.001 in (0.025 mm) nominal
Operating Temperature–60 °F to +200 °F (–50 °C to +93 °C)
Compensated Temperature60 – 160 °F (15 – 72 °C)
Cable / Wiring29 AWG, 4-conductor, spiral shielded Teflon cable (~10 ft)
Weight~2 oz (57 g)
IP RatingIP64 (for standard versions)

Typical Applications of the Donut Through-Hole Load Cell LTH300

The Donut Through-Hole Load Cell (LTH300) is ideal for:

  • Measuring bolt preload / clamping forces in assemblies

  • Inline compression sensing for press, stamping, or load washer systems

  • Load monitoring in machinery where a bolt or shaft must pass through the sensor

  • Structural or fixture designs where traditional load cells cannot be placed around the load path

  • Inline force sensing in manufacturing or test systems where space is tight


Why Choose the Donut Through-Hole Load Cell LTH300

  • True through-hole design allows the load path to pass unhindered, simplifying mechanical integration.

  • Reliable accuracy even under dynamic loading and temperature variation.

  • Overload protection and durability guard the sensor against installation torque or transient loads.

  • Compact footprint designed for tight assemblies with minimal added height.

  • Support & calibration – Metromatics can assist with matching ID sizes, calibration, integration, and mounting guidance.


Donut Load Cell LTH300 Models

Item

Load CapacityInner Diametre cmOuter Diametre cmHeight cmLength cmWidth cm

Connection Type

FSH03959

4448.22 N0.9525 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH039602224.11 N0.9525 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH03961

1112.06 N0.9525 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH03962444.822 N0.9525 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH03963

222.411 N0.9525 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH039644448.22 N0.79 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH03966

4448.22 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH039672224.11 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH03968

444.822 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH03969222.411 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH03970

444.822 N0.32 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH040461112.06 N0.79 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH04047

444.822 N0.79 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH04048222.411 N0.79 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH04049

1112.06 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH040502224.11 N0.48 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

FSH04051

222.411 N0.48 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
FSH046151112.06 N

FSH04616

222.411 N

QSH010672224.11 N0.48 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

QSH01567

2224.11 N0.95 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
QSH0175422.2411 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable & Connector

QSH01861

111.206 N0.635 cm2.49 cm0.71 cm2.49 cm2.49 cmCable
QSH02071222.411 N0.95 cm2.49 cm0.71 cm2.49 cm2.49 cm

Cable

Ordering & Configuration Notes

If you would like to learn more about this product or would like to place an order, please contact us.

When ordering an LTH300, consider:

  1. Inner diameter (I.D.) selection – choose the correct bore size to match your bolt, shaft, or structure (1/8″, 1/4″, 5/16″, 3/8″).

  2. Capacity selection – select a sensor that comfortably exceeds your maximum expected load to maintain linearity and protect against overload.

  3. Cable length / connector options – standard 10 ft Teflon cable; if you need shorter or custom wiring, request modifications.

  4. Calibration & matching – request compressive calibration, traceable certification, or matched output if needed for system consistency.

  5. Environmental conditions – verify that operating temperature range, IP rating, and mechanical deflection suit your application.

 