CRY3408-S01 High-SPL Pressure-Field Microphone Set

The CRYSOUND CRY3408-S01 is a 180 dB pressure-field microphone set for blast, impulse and other extreme high-sound-pressure measurements.

Its verified 10 Hz to 20 kHz ±2 dB response and 70 dB to 180 dB dynamic range help acoustic engineers match sensitivity and measurement headroom to the test environment.

In addition, its IEPE, 10-32UNF (Microdot) configuration defines how it connects to the measurement chain.

High-SPL Pressure-Field Microphone Set for Application-Focused Engineering

CRY3408-S01 uses a prepolarized sensing element for free-field measurement and is supplied as a matched microphone and preamplifier set. Free-field response is relevant where the microphone measures sound arriving without dominant reflections, such as in anechoic rooms, controlled test areas and many product-noise setups. Selection should consider the expected minimum and maximum sound level, bandwidth, field type and connector.

Key Features and Benefits

  • 14 mV/Pa (-77 ±3 dB re 1 V/Pa) nominal sensitivity.
  • 10 Hz to 20 kHz ±2 dB frequency response.
  • 70 dB to 180 dB dynamic range.
  • IEPE, 10-32UNF (Microdot).
  • IEC 61094-4 type WS3P.
  • Operating temperature: -30°C to +70°C.
  • Prepolarized design eliminates the need for an external polarisation voltage.

Technical Specifications

SpecificationCRYSOUND CRY3408-S01
Field typePressure-field
Nominal sensitivity0.14 mV/Pa (-77 ±3 dB re 1 V/Pa)
Frequency response10 Hz to 20 kHz ±2 dB
Polarisation voltage0 V
Dynamic range70 dB to 180 dB
Interface / poweringIEPE, 10-32UNF (Microdot)
IEC 61094-4 typeWS3P
Operating temperature-30°C to +70°C
Dimensions56.2 mm × 7 mm
Pressure equalisationSide vented

 

Applications

  • Blast and impulsive-noise measurement
  • Airbag deployment and high-power equipment testing
  • Industrial high-SPL acoustic measurement
  • Large-equipment noise testing

Integration and Configuration Considerations

The complete set includes the microphone and IEPE preamplifier. Confirm the data-acquisition input supports the stated constant-current supply and connector. TEDS is included only where shown in the specifications.

Selecting the Measurement Chain

Accurate acoustic measurement depends on the complete signal chain. Therefore, confirm the microphone field type, sensitivity, dynamic range, preamplifier, connector, cable, constant-current supply, data-acquisition input and calibration method as one system. Metromatics can help review these interfaces before quotation.

Why Source the CRY3408-S01 Through Metromatics?

Finally, Metromatics can help Australian and New Zealand customers compare the CRY3408-S01 with other CRYSOUND measurement options and review the intended sound field, level range, bandwidth, connector and acquisition requirements.

Contact Metromatics to discuss your application, confirm the correct CRY3408-S01 configuration, obtain additional technical information or request pricing.

EN-CRY3408-S01 Measurement Microphone