CRY3203 High-Sensitivity Free-Field Microphone

The CRYSOUND CRY3203 is a 1/2-inch prepolarized measurement microphone for audible-range acoustic testing where a separate compatible preamplifier is used.

Its verified 3.15 Hz to 20 kHz ±2 dB response and 16 dBA to 146 dB dynamic range help acoustic engineers match sensitivity and measurement headroom to the test environment.

In addition, its Prepolarized cartridge; compatible CRYSOUND IEPE preamplifier required configuration defines how it connects to the measurement chain.

High-Sensitivity Free-Field Microphone for Application-Focused Engineering

CRY3203 uses a prepolarized sensing element for free-field measurement. It is a microphone cartridge and must be paired with a compatible preamplifier. Free-field response is relevant where the microphone measures sound arriving without dominant reflections, such as in anechoic rooms, controlled test areas and many product-noise setups. Selection should consider the expected minimum and maximum sound level, bandwidth, field type and connector.

Key Features and Benefits

  • 50 mV/Pa (-26 ±1.5 dB re 1 V/Pa) nominal sensitivity.
  • 15 Hz to 20 kHz ±2 dB frequency response.
  • 16 dBA to 146 dB dynamic range.
  • Prepolarized cartridge; compatible CRYSOUND IEPE preamplifier required.
  • IEC 61094-4 type WS2F.
  • Operating temperature: -30°C to +80°C.
  • Prepolarized design eliminates the need for an external polarisation voltage.

Technical Specifications

SpecificationCRYSOUND CRY3203
Field typeFree-field
Nominal sensitivity50 mV/Pa (-26 ±1.5 dB re 1 V/Pa)
Frequency response3.15 Hz to 20 kHz ±2 dB
Polarisation voltage0 V
Dynamic range16 dBA to 146 dB
Interface / poweringPrepolarized cartridge; compatible CRYSOUND IEPE preamplifier required
IEC 61094-4 typeWS2F
Operating temperature-30°C to +80°C
Dimensions16.2 mm × 13.2 mm
Pressure equalisationRear vented

 

Applications

  • Anechoic-chamber and quiet-room testing
  • Electroacoustic and audio measurement
  • Product noise and quality-control testing
  • Acoustic research and development
  • Automotive noise, vibration and harshness testing

Integration and Configuration Considerations

This product is the microphone cartridge rather than a complete microphone set. Pair it with a mechanically and electrically compatible CRYSOUND preamplifier, then confirm power supply, cable, connector and data-acquisition input requirements.

Selecting the Measurement Chain

Accurate acoustic measurement depends on the complete signal chain. Therefore, confirm the microphone field type, sensitivity, dynamic range, preamplifier, connector, cable, constant-current supply, data-acquisition input and calibration method as one system. Metromatics can help review these interfaces before quotation.

Why Source the CRY3203 Through Metromatics?

Metromatics can help Australian and New Zealand customers compare the CRY3203 with other CRYSOUND measurement options.  Help review the intended sound field, level range, bandwidth, connector and acquisition requirements before quotation.

Contact Metromatics to discuss your application, confirm the correct CRY3203 configuration, obtain additional technical information or request pricing.