CRY3501 Measurement Microphone Preamplifier

The CRYSOUND CRY3501 is a 1/2-inch IEPE microphone preamplifier with BNC connector for connecting compatible prepolarized measurement microphones to constant-current acquisition systems.

It converts the microphone’s high-impedance signal to a low-output-impedance signal, supporting longer cable runs with limited loading.

Its BNC connection and 1 Hz to 200 kHz (±0.2 dB) response make it important to match the preamplifier to the microphone, cable and analyser.

Measurement Microphone Preamplifier for Application-Focused Engineering

A measurement microphone capsule produces a high-impedance signal that should not be routed directly over a long cable. This preamplifier buffers that signal and presents a lower output impedance to the acquisition system. Therefore, it forms a critical part of the measurement chain and must be selected by capsule size, threaded coupling, connector, IEPE supply and available installation space.

Key Features and Benefits

  • 1 Hz to 200 kHz (±0.2 dB) frequency response.
  • BNC output connector.
  • Compact 80 mm × 12.7 mm mechanical envelope.
  • A-weighted noise <2.6 µV rms.
  • IEPE constant-current power supply.
  • Output impedance below 50 Ω.
  • Total harmonic distortion below 0.1%.
  • IEEE 1451.4 TEDS support where stated by the manufacturer.

Technical Specifications

SpecificationCRYSOUND CRY3501
Compatible microphone format1/2-inch CRY3000 series
Frequency response1 Hz to 200 kHz (±0.2 dB)
Output impedance<50 Ω
Total harmonic distortion<0.1%
Power supplyIEPE, 2 mA to 20 mA
Nominal operating current4 mA
A-weighted noise<2.6 µV rms
DC bias voltage12 V ±2 V
ConnectorBNC
Operating temperature-40°C to +80°C
Threaded coupling11.7-60 UNS
Dimensions80 mm × 12.7 mm

 

Applications

  • Laboratory acoustic measurement systems
  • Product-noise and electroacoustic testing
  • Microphone arrays and multi-channel acquisition
  • Anechoic-room measurement
  • Field measurement with extended cables

Integration and Configuration Considerations

Confirm that the selected measurement microphone uses the correct diameter and thread and that the data-acquisition system provides a compatible IEPE supply. The BNC connector determines the required cable. In addition, check TEDS support across the preamplifier, cable and acquisition channel if automatic sensor identification is required.

Selecting the Measurement Chain

Accurate acoustic measurement depends on the complete signal chain. Therefore, confirm the microphone field type, sensitivity, dynamic range, preamplifier, connector, cable, constant-current supply, data-acquisition input and calibration method as one system. Metromatics can help review these interfaces before quotation.

Why Source the CRY3501 Through Metromatics?

Metromatics can help Australian and New Zealand customers compare the CRY3501 with other CRYSOUND measurement options and review the intended sound field, level range, bandwidth, connector and acquisition requirements before quotation.

Contact Metromatics to discuss your application, confirm the correct CRY3501 configuration, obtain additional technical information or request pricing and a quotation.

CRY3501-Datasheet