CRY3401-S01 Quarter-Inch Free-Field Microphone Set

The CRYSOUND CRY3401-S01 is a 1/4-inch high-frequency microphone set for low-noise, high-definition audio and ultrasonic acoustic testing.

Its verified 4 Hz to 40 kHz ±2 dB response and 26 dBA to 146 dB dynamic range help acoustic engineers match sensitivity and measurement headroom to the test environment.

In addition, its IEPE, SMB configuration defines how it connects to the measurement chain.

Quarter-Inch Free-Field Microphone Set for Application-Focused Engineering

CRY3401-S01 uses a prepolarized sensing element for free-field measurement and is supplied as a matched microphone and preamplifier set. Free-field response is relevant where the microphone measures sound arriving without dominant reflections, such as in anechoic rooms, controlled test areas and many product-noise setups. Selection should consider the expected minimum and maximum sound level, bandwidth, field type and connector.

Key Features and Benefits

  • 8 mV/Pa (-36 ±1.5 dB re 1 V/Pa) nominal sensitivity.
  • 4 Hz to 40 kHz ±2 dB frequency response.
  • 26 dBA to 146 dB dynamic range.
  • IEPE, SMB.
  • IEC 61094-4 type WS3F.
  • Operating temperature: -20°C to +60°C.
  • Prepolarized design eliminates the need for an external polarisation voltage.

Technical Specifications

SpecificationCRYSOUND CRY3401-S01
Field typeFree-field
Nominal sensitivity15.8 mV/Pa (-36 ±1.5 dB re 1 V/Pa)
Frequency response4 Hz to 40 kHz ±2 dB
Polarisation voltage0 V
Dynamic range26 dBA to 146 dB
Interface / poweringIEPE, SMB
IEC 61094-4 typeWS3F
Operating temperature-20°C to +60°C
Dimensions56.2 mm × 7 mm
Pressure equalisationSide vented

 

Applications

  • Anechoic-chamber and quiet-room testing
  • Electroacoustic and audio measurement
  • Product noise and quality-control testing
  • Acoustic research and development
  • Automotive noise, vibration and harshness testing

Integration and Configuration Considerations

The complete set includes the microphone and IEPE preamplifier. Confirm the data-acquisition input supports the stated constant-current supply and connector. TEDS is included only where shown in the specifications.

Selecting the Measurement Chain

Accurate acoustic measurement depends on the complete signal chain. Therefore, confirm the microphone field type, sensitivity, dynamic range, preamplifier, connector, cable, constant-current supply, data-acquisition input and calibration method as one system. Metromatics can help review these interfaces before quotation.

Why Source the CRY3401-S01 Through Metromatics?

Metromatics can help Australian and New Zealand customers compare the CRY3401-S01 with other CRYSOUND measurement options.  Help review the intended sound field, level range, bandwidth, connector and acquisition requirements before quotation.

Contact Metromatics to discuss your application, confirm the correct CRY3401-S01 configuration, obtain additional technical information or request pricing and a quotation.