Thermocouple / millivolt Input Loop-Power Transmitter 655T 656T

Thermocouple mV Input Loop-Power Transmitter 655T 656T

These units accept universal thermocouple types J, K, T, R, S, E, B, N and ±1V DC selectable type input signals, provide isolation and output proportional DC current signals. The output can be linearised to input sensor signal.

655T Single TC/mV Input Channel

656T Dual TC/mV Input Channel

Ethernet Analog IO Modules NT2240

Ethernet Analog IO Modules NT2240

The NT2240 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. This type of model offers a compact network interface to monitor sensor levels or 0-10V Devices.

NTX Expansion models can interface up to 64 voltage inputs on a single IP address.

Ethernet Analog IO Modules NT2230

Ethernet Analog IO Modules NT2230

The NT2230 modules offer 8 differential voltage inputs and 2 limit alarms. Each input has true differential 16-bit A/D Card. The NTE Ethernet Models provide a compact network interface to monitor 0-10 or sensor level devices.

NTX Expansion models can interface up 32 differential voltage inputs on a single IP address.

Ethernet Analog IO Modules NT2220

Ethernet Analog IO Modules NT2220

The NT2220 modules offer 16 current inputs. Each input supports bipolar and unipolar ranges with 16-bit A/D. This type of model offers a compact network interface to monitor sensor levels or 4-20mA loops.

NTX Expansion models can interface up to 64 current inputs on a single IP address.

Ethernet Analog IO Modules NT2210

Ethernet Analog IO Modules NT2210

The NT2210 modules offer 8 current inputs and 2 limit alarms. Each input has true differential 16-bit A/D. This type of model offers a compact network interface to monitor sensor levels or 4-20mA loops.

NTX Expansion models can interface up to 32 differential current inputs on a single IP address.

AC/DC Powered signal splitter 633T

AC/DC Powered signal splitter 633T

The 633T is a signal splitter that receive 4-20mA process current inputs and provide two 4 to 20mA Output signals. Each channel operates independently.

They are isolated from the other to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise and blocks transient signals.

4-20mA Signal Isolator DT236

4-20mA Signal Isolator DT236

Model DT236 is a dual two-wire transmitter that isolates and converts a DC current or low voltage inputs to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

  • Dual channels ±20mA, ±500mV inputs
  • 4-20mA outputs (sink/source)
  • 7-32V DC loop power

Millivolt signal converters

The Acromag millivolt Signal Converters are convenient and easy to use.  Firstly, these signal transmitters convert -50 to 375mV DC sensor input signals to 4-20mA or 0-1-V DC outputs for interfacing to controllers or other instrumentation.

Metromatics provides excellent local customer service and sales for this product range in Australia.

DC Voltage or Current Input Signal Converter

The Acromag DC Voltage or Current Input Signal Converters are convenient and easy.  Firstly, you can convert DC Input signals to 4-20mA or 0-10V DC Outputs.  Secondly, these output signals are used for interfacing to controllers and other instrumentation.

Metromatics provides excellent local customer service and sales for this product range in Australia.