CRY3401 Low-Noise Quarter-Inch Microphone

The CRYSOUND CRY3401 is a 1/4-inch prepolarized free-field microphone for low-noise and high-frequency testing up to 40 kHz.

Its verified 4 Hz to 40 kHz ±2 dB response and 26 dBA to 144 dB dynamic range help acoustic engineers match sensitivity and measurement headroom to the test environment.

In addition, its Prepolarized cartridge; compatible 1/4-inch preamplifier required configuration defines how it connects to the measurement chain.

Low-Noise Quarter-Inch Microphone for Application-Focused Engineering

CRY3401 uses a prepolarized sensing element for free-field measurement. It is a microphone cartridge and must be paired with a compatible preamplifier. Free-field response is relevant where the microphone measures sound arriving without dominant reflections, such as in anechoic rooms, controlled test areas and many product-noise setups. Selection should consider the expected minimum and maximum sound level, bandwidth, field type and connector.

Key Features and Benefits

  • 8 mV/Pa (-36 ±1.5 dB re 1 V/Pa) nominal sensitivity.
  • 4 Hz to 40 kHz ±2 dB frequency response.
  • 26 dBA to 144 dB dynamic range.
  • Prepolarized cartridge; compatible 1/4-inch preamplifier required.
  • IEC 61094-4 type WS3F.
  • Operating temperature: -20°C to +60°C.
  • Prepolarized design eliminates the need for an external polarisation voltage.

Technical Specifications

SpecificationCRYSOUND CRY3401
Field typeFree-field
Nominal sensitivity15.8 mV/Pa (-36 ±1.5 dB re 1 V/Pa)
Frequency response4 Hz to 40 kHz ±2 dB
Polarisation voltage0 V
Dynamic range26 dBA to 144 dB
Interface / poweringPrepolarized cartridge; compatible 1/4-inch preamplifier required
IEC 61094-4 typeWS3F
Operating temperature-20°C to +60°C
Dimensions10.5 mm × 7 mm
Pressure equalisationSide vented

 

Applications

  • Anechoic-chamber and quiet-room testing
  • Electroacoustic and audio measurement
  • Product noise and quality-control testing
  • Acoustic research and development
  • Automotive noise, vibration and harshness testing

Integration and Configuration Considerations

This product is the microphone cartridge rather than a complete microphone set. Pair it with a mechanically and electrically compatible CRYSOUND preamplifier, then confirm power supply, cable, connector and data-acquisition input requirements.

Selecting the Measurement Chain

Accurate acoustic measurement depends on the complete signal chain. Therefore, confirm the microphone field type, sensitivity, dynamic range, preamplifier, connector, cable, constant-current supply, data-acquisition input and calibration method as one system. Metromatics can help review these interfaces before quotation.

Why Source the CRY3401 Through Metromatics?

Metromatics can help Australian and New Zealand customers compare the CRY3401 with other CRYSOUND measurement options and review the intended sound field, level range, bandwidth, connector and acquisition requirements before quotation.

Contact Metromatics to discuss your application, confirm the correct CRY3401 configuration, obtain additional technical information or request pricing and a quotation.