Thrust and Moment Load Cell MTA505

The Thrust and Moment Load Cell MTA505 is a low-profile multi-axis (triaxial) load cell designed to measure thrust (Fz) and moments (Mx, My) simultaneously in a compact package. With a flange-type geometry, 150% safe overload, precision performance, and stainless steel construction, it’s ideal for wind tunnel models, test stands, misalignment quantification, structural load measurement, and multi-axis instrumentation.

Key Features & Benefits of the Thrust and Moment Load Cell MTA505

  • Multi-Axis Sensing — measure Fz (thrust) and Mx / My (moments) in one sensor without needing separate devices.

  • Low Profile Design — compact form factor requiring minimal space in your mechanical assemblies.

  • High Overload Protection — safe overload rating of 150% of rated output (RO) for added robustness.

  • Strong Accuracy & Repeatability

    • Nonlinearity for Mx/My: ±0.5% of RO

    • Nonlinearity for Fz: ±0.2% of RO

    • Cross-talk: ±2% of RO or better

  • Electrical & Connectivity Features

    • Excitation: up to 18 VDC / VAC

    • Bridge Resistance: 350 Ω nominal

    • Insulation Resistance: ≥ 500 MΩ @ 50 VDC

    • Connection: (3) 6-pin Bendix® receptacles (PT02A-10-6P)

  • Mechanical & Material

    • Material (flexure): 17-4 PH stainless steel

    • Weight: ~20 lb (≈ 9.3 kg)

    • IP Rating: IP65

  • Temperature Performance & Stability

    • Operating Temperature: –65 to +200 °F (–54 to +93 °C)

    • Compensated Temperature: 60 to 160 °F (15 to 72 °C)

    • Temperature Shift (Zero): ±0.01% RO / °F (~0.018% / °C)

    • Temperature Shift (Span): ±0.01% of Load / °F (~0.018% / °C)


Technical Specifications of the Thrust and Moment Load Cell MTA505

ParameterSpecification / Value
Performance
Nonlinearity (Mx, My)±0.5 % of Rated Output (RO)
Nonlinearity (Fz)±0.2 % of RO
Cross Talk±2 % of RO or less
Electrical
Rated Output (RO)See chart (capacity-dependent)
Excitation (max)18 VDC or VAC
Bridge Resistance350 Ω (nominal)
Insulation Resistance≥ 500 MΩ at 50 VDC
Connection(3) 6-pin BENDIX® receptacles, model PT02A-10-6P
Connector CodeCC1
Mechanical / Structural
Weight~20 lb (≈ 9.3 kg)
Safe Overload150 % of RO
Material (Flexure)17-4 PH stainless steel
IP RatingIP65
Temperature
Operating Temperature–65 to +200 °F (–54 to +93 °C)
Compensated Temperature60 to 160 °F (15 to 72 °C)
Temperature Shift — Zero±0.01 % of RO per °F (≈ 0.018 % / °C)
Temperature Shift — Span±0.01 % of load per °F (≈ 0.018 % / °C)
Capacities & Physical / Dynamic Specs
Capacities (Fz / Mx, My)• 10,000 lb / 2,000 in-lb
• 25,000 lb / 10,000 in-lb
Deflection (Fz only)0.001 in for 10,000 lb model; ~0.002 in for 25,000 lb model
Natural Frequency (Fz only)~7,100 Hz (for both variants)
Rated Output (mV/V)• 10,000 lb: 2.5 mV/V (Fz), 0.5 mV/V (Mx/My)
• 25,000 lb: 4 mV/V (Fz), 2 mV/V (Mx/My)
Zero Balance±2 % of RO
CalibrationStandard: 5-point compression (CW)
Optional: 5-point tension (CCW)
Shunt Calibration Values: 43.575 kΩ (10,000 lb) / 30 kΩ (25,000 lb)
Dimensions & Mechanical LayoutSee FUTEK’s drawing FI1288-E for full dimensions (outer diameter, inner hole, mounting threads, “D” moment reference)

Typical Applications of the Thrust and Moment Load Cell MTA505

  • Measurement of misalignment in test stands or structural assemblies

  • Wind tunnel model testing for aerodynamic loads

  • Structural and mechanical force & moment analysis

  • Multi-axis load sensing in test rigs, actuators, or frames

  • OEM systems requiring compact multi-component force instrumentation


Why Choose the Thrust and Moment Load Cell MTA505

  • Multi-axis in a compact design — reduces cabling, alignment errors, and system complexity

  • Accurate and robust — tight specs, 150% overload protection, and IP-rated sealing

  • Flexible & configurable — multiple capacity options, calibration variants, and connector interface

  • Support & calibration services — help with installation, wiring, calibration, and system integration

  • Trusted brand & build quality — USA-made, strain gauge technology trusted across industrial and test applications


Ordering & Configuration Notes

If you would like more information about this product, please contact us.

When ordering an MTA505, consider:

  1. The capacity variant (Fz / Mx, My) matching your expected loads

  2. Whether you need the 10,000 / 2,000 in-lb model or the 25,000 / 10,000 in-lb version

  3. Calibration options — standard 5-pt compression (CW) or optional tension / CCW

  4. Connector considerations — uses 3 × Bendix 6-pin receptacles (PT02A-10-6P)

  5. System compatibility — wiring, signal conditioning, shunt calibrations, and mechanical mounting

 

Low Profile Multi Axis Load Cell MTA505 Versions

Item

Load CapacityTorque CapacityLength in cmHeight in cmWidth in cmOuter diameter cm

# of Axis

FSH02453

44482.2 N225.97 N-m15.19 cm8.89 cm

 

15.19 cm15.19cm3
FSH02299111206 N1129.85 N-m15.19 cm8.89 cm

 

15.19 cm15.19cm

3

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.